The correct use of ultrasonic cleaning machine (ultrasonic cleaning machine operating procedures detailed)

Using the ultrasonic cleaning machine operating procedures.

1、Put the items to be cleaned into the cleaning basket of the cleaning machine, and then put the cleaning basket into the cleaning tank. Please do not put the items directly into the cleaning tank, so as not to damage the equipment and affect the cleaning effect.

2、According to different products or cleaning effect, pour in cleaning solution, water or aqueous solution in proportion, the minimum water level should not be lower than the minimum water level marked in the product manual, and the maximum water level should not exceed the maximum water level marked in the product manual.

3、connect 220V/50Hz power three-prong socket, turn on the power.

4、open the ultrasonic cleaning machine switch button, green switch on the normal operation.

5、open the ultrasonic cleaning machine temperature control, according to the item cleaning requirements to adjust the temperature.

6、the temperature indicator goes off, the heater reaches the required requirements, the heater stops working, if lower than the set temperature, the heater will continue to automatically heat.

7、When the heating temperature reaches the product cleaning requirements, the cleaning timer can be turned on, and the working time of the timer can be set according to the product cleaning requirements.

8、The cleaning time of general items is 10 minutes to 20 minutes. For cleaning difficult workpieces, the cleaning time can be extended appropriately to ensure the cleaning effect.

9、The timer position can be adjusted arbitrarily within 1-20min, also can be adjusted in the normally open position. The general cleaning time is 10-20min. for the cleaning of particularly difficult parts, the cleaning time can be extended appropriately.

10、After cleaning, the cleaning tank remove the cleaning basket, rinse with warm water or in another solvent-free warm water cleaning tank.

11、items should be dried, stored and assembled after cleaning.

Precautions when using ultrasonic cleaning machine.

1、in order to prolong the service life, it is recommended to put the equipment in a ventilated, dry area, the fan hole on the back side of the generator should be cleaned regularly. The generator is left with vents on all sides to make the airflow unobstructed.

2、When the temperature of the cleaning cylinder is room temperature, do not inject the high temperature liquid directly into the cylinder, so as not to cause the transducer to loosen and affect the normal use of the machine.

3、when the cleaning fluid needs to be replaced due to pollution, do not inject the low-temperature liquid directly into the high-temperature cylinder, which can also lead to the transducer off, and should close the heater switch, so as not to damage the heater because there is no liquid in the tank.

4、the cleaning tank must be put into the liquid before the machine can work, the minimum water level height > 100mm (bottom vibration type) and placed horizontally, the transducer in the side, the cleaning tank tank edge 100mm, such as in the air state will damage the machine.

5、regular inspection of the transducer, do not make it damp and impact, so as not to cause unnecessary losses. After use, the total power should be turned off. Do not restart the machine immediately after shutdown, the gap time should be more than 1 minute.